Research
What we are investigating, and how
Each area below is framed as a question rather than a capability, because that is honestly where most of them still are. The status label reflects the state of the work, not the state of our intentions.
- In Progress
Soil pH
- Question
- Can a field-deployable probe track soil pH closely enough to be useful for deciding whether nutrients already present are available to a crop?
- Method
- Repeated readings at fixed points, compared against laboratory analysis of samples taken from the same location and depth on the same day, across a range of soil moisture states.
- Current status
- pH is the most tractable of our target measurements. The dominant error source so far is not the sensor but the sampling — probe placement and soil contact vary more than expected between readings.
- In Progress
Electrical Conductivity
- Question
- How reliably does bulk EC indicate meaningful variation in soil condition across a single field, once moisture and temperature are accounted for?
- Method
- Paired EC and volumetric moisture readings on a fixed grid, with temperature logged at probe depth, to build a correction model before EC is interpreted at all.
- Current status
- EC responds strongly to moisture, so raw readings taken on different days are not comparable. Correction is a prerequisite for any spatial interpretation, not an optional refinement.
- In Progress
Soil Moisture
- Question
- What sampling frequency and depth is needed for moisture data to be useful both on its own and as a correction input for other measurements?
- Method
- Multi-depth logging at fixed stations through wetting and drying cycles, checked against gravimetric measurement of extracted samples.
- Current status
- Capacitive sensing is workable but soil-specific; calibration derived from one soil texture transfers poorly to another. We are treating per-site calibration as mandatory rather than optional.
- In Progress
NPK Indicators
- Question
- Which nutrient information can be obtained in-field at reasonable cost, and which cannot — and how should the difference be communicated?
- Method
- Literature review plus direct comparison of candidate sensing approaches against laboratory nutrient panels on identical samples.
- Current status
- This is where we are most cautious. Phosphorus and potassium indicators show some correlation with laboratory values in our early data; nitrogen does not, at the cost point we are targeting. We would rather report nitrogen as unavailable than present a weakly-correlated proxy as a measurement.
- Planned
Spatial Interpolation & GIS
- Question
- How many sample points does a field need before an interpolated map is more informative than misleading?
- Method
- Dense sampling of a small test area, then progressive subsampling to measure how quickly interpolated surfaces diverge from the fully-sampled reference.
- Current status
- Not yet started. A smooth map drawn from too few points is the failure mode we most want to avoid, because it looks authoritative regardless of how little data underlies it.
- In Progress
Recommendation Framework
- Question
- Can an interpretation layer present agronomic context without implying more certainty than the underlying measurements support?
- Method
- Rule-based agronomic logic derived from published guidance, with explicit confidence propagation and a hard abstention path when inputs fall outside validated ranges.
- Current status
- Under active design. The current constraint is that "insufficient data" must be a first-class output the system reaches often, not an error state it avoids.
LupaIQ is currently an independent research initiative. Information presented on this website reflects ongoing development and should not be interpreted as commercial agricultural recommendations.
Open Questions
What we do not know yet
This section is the one we would most like reviewed. If any of these look like solved problems to you, or if we have missed something more serious, we would genuinely like to hear it.
We have not yet validated against enough soil types
Calibration developed on one soil texture does not transfer cleanly to another. Until the prototype has been tested across a meaningfully varied set of sites, any accuracy figure we could quote would describe a narrower situation than it appears to.
Nitrogen remains largely inaccessible to us
Plant-available nitrogen changes quickly and is difficult to sense directly at low cost. We do not currently have an approach we would trust, and we would rather state that plainly than present an inference as a reading.
Sampling error may exceed sensor error
Early results suggest that where and how a probe is inserted introduces more variation than the instrument itself. This shifts the problem toward protocol design, which is less interesting than sensor work and probably more important.
We have no multi-season data
Soil properties shift across a season and between years. Nothing we have measured yet spans enough time to say anything about trends, which is precisely where the value of continuous monitoring would lie.
Field durability is untested
Laboratory-bench reliability tells us little about hardware left in soil through heat, rain, and cultivation. This has not been assessed and should be assumed unproven.
The recommendation logic has not been reviewed by agronomists
Our interpretation rules are derived from published guidance, assembled by engineers. They need review by people with formal agronomic training before they are put in front of anyone making a real decision.
Review our methodology
We are looking for soil scientists, agronomists, and instrumentation researchers willing to examine how we are measuring and interpreting — particularly where our approach is weakest.