The first version of the LupaIQ probe was not built to be good. It was built to find out whether the approach was viable enough to justify building something that is.
The constraint we set was cost. There is no shortage of accurate soil instrumentation available today; there is a shortage of instrumentation a smallholder can justify buying. So the question was never "can this be measured" — it was "can this be measured well enough, at a price that makes regular use realistic."
What version one does
The first build reads four things: soil temperature, volumetric moisture, electrical conductivity, and pH. Everything is logged with a timestamp, a GPS fix, and the probe's insertion depth, because a reading without that context turned out to be nearly useless the moment we tried to compare two of them.
Nitrogen, phosphorus, and potassium are not measured. This was the first significant scope decision we made and it was not a comfortable one — NPK is what most people expect from a soil tool. We will come back to why in a later entry.
What went wrong immediately
Three things, in order of how much time they cost us:
-
Soil contact dominates everything. Two readings taken thirty centimetres apart differed more than two readings taken a week apart at the same point. We initially assumed sensor noise. It was not; it was how well the probe was seated against the soil.
-
EC without moisture is meaningless. We knew this from the literature and still underestimated it. The same location read differently on consecutive days purely because it had rained. Any interpretation layer has to correct for moisture before it does anything else.
-
Power budget was wrong by a factor of about three. Continuous logging drained the battery faster than the enclosure could be practically serviced. Version two logs on an interval and sleeps between readings.
What we learned that we did not expect
The most useful realisation was that our error was mostly not in the electronics. It was in the protocol — where the probe goes, how deep, how it is seated, how often. That is a less interesting engineering problem than sensor design, and considerably more important to get right.
Version two is being specified now. The main changes are mechanical rather than electronic: a fixed-depth stop, a different tip geometry to improve soil contact, and a documented insertion procedure that produces repeatable results when followed by someone who did not build it.